dc.contributor.author | Puong, Ling Law | |
dc.contributor.author | Chong, Gracie S. C. | |
dc.contributor.author | Chee, Khoon Ng | |
dc.date.accessioned | 2011-09-07T19:16:08Z | |
dc.date.available | 2011-09-07T19:16:08Z | |
dc.date.issued | 2005-06 | |
dc.identifier.citation | The Journal of the Institution of Engineers, Malaysia, vol. 66(2), 2005, pages 32-37 | en_US |
dc.identifier.issn | 0126-513X | |
dc.identifier.uri | http://www.myiem.org.my/content/iem_journal_2005-176.aspx | |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/13680 | |
dc.description | Link to publisher's homepage at http://www.myiem.org.my/ | en_US |
dc.description.abstract | A model for prioritisation of industrial air pollutants was recently developed for use in Sama Jaya Free Industrial Zone
(SJFIZ), Kuching based on the amount of toxic organic chemicals released into the atmosphere through stack and fugitive
emissions. The Chemical Health Risk Index Number (CHRIN) rankings generated by this model indicate that xylene, among
all chemicals emitted has the greatest health impact in terms of population and workers exposure with highest CHRIN of
4.246, followed by methyl ethyl ketone (3.153), trichloroethylene (2.244), ethylene glycol (2.214), methanol (1.697), toluene
(1.479) and ethylbenzene (0.610). It is concluded that manufacturing facilities in SJFZ should devote its resources and
research more effectively on xylene, followed by methylene ethyl ketone, trichloroethylene, ethylene glycol, methanol, toluene
and theylbenzene on use reduction technologies and methods. | en_US |
dc.language.iso | en | en_US |
dc.publisher | The Institution of Engineers, Malaysia | en_US |
dc.subject | Chemical Health Risk Index Number (CHRIN) | en_US |
dc.subject | Ethylbenzene | en_US |
dc.subject | Ethylene glycol | en_US |
dc.subject | Industrial air pollutant | en_US |
dc.subject | Model | en_US |
dc.subject | Methanol | en_US |
dc.subject | Methylene ethyl ketone | en_US |
dc.subject | Prioritisation | en_US |
dc.subject | Health Impacts | en_US |
dc.subject | Trichloroethylene | en_US |
dc.subject | Xylene | en_US |
dc.title | A model for prioritisation of industrial air pollutants: Part II. Application | en_US |
dc.type | Article | en_US |