dc.descriptionInternational Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Perlis, Malaysia.en_US
dc.description.abstractEpstein test is well known method to test the specific total loss in magnetic material. Epstein test procedures are complicated as well as destructive test. Therefore, the Iron Loss Tester is an alternative test and can be use in Incoming Quality Assurance (IQA) check. This paper demonstrates the Iron Loss Tester in application of IQA check. In addition, this paper also shows the statistic comparison analysis for Epstein and Iron Loss Tester. Furthermore, together with statistic distribution analysis, this paper illustrates the capabilities of Iron Loss Tester in testing electrical steel.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.relation.ispartofseriesProceedings of the International Postgraduate Conference on Engineering (IPCE 2010)en_US
dc.subjectEpstein testen_US
dc.subjectIron Loss Testen_US
dc.subjectSpecific core lossen_US
dc.titleEpstein and iron loss test for Incoming Quality Assurance (IQA)en_US