• Login
    View Item 
    •   DSpace Home
    • The Library
    • Conference Papers
    • View Item
    •   DSpace Home
    • The Library
    • Conference Papers
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Measurement and simulation of current total harmonic distortion on three-level single phase transformerless photovoltaic inverter

    Thumbnail
    View/Open
    Access is limited to UniMAP community (510.4Kb)
    Date
    2012-06-18
    Author
    Ismail, Daut, Prof. Dr.
    Muhammad Irwanto
    Tunku Muhamad Nizar, Tunku Mansur
    Rosnazri, Ali
    Nair, Gomes
    Mohd Irwan, Yusoff
    Muhammad, Fitra
    Metadata
    Show full item record
    Abstract
    This paper presents a new topology of three-level transformerless photovoltaic (PV) inverter. It consists of three main circuits; they are a pulse driver circuit, a full bridge inverter circuit and a power factor correction circuit that have functions as production of pulse waves, to develop alternating current (AC) waveform and to stable voltage of PV array, respectively. The transformerless PV inverter is installed in front of Centre of Excellent for Renewable Energy (CERE), Universiti Malaysia Perlis, Northern Malaysia. Its main energy source is a PV array that consists of three unit PV modules, each unit has 81 V, 60 W. In this research, optimization of current total harmonic distortion (CTHD) on AC three-level waveform transformerless PV inverter is developed and created by a microcontroller PIC16F627A-I/P with change maximum voltage angle of the AC three-level waveform from 200 to 1800. Resistive load of 30 W lamp and inductive load of 20 W water pump are applied to the transformerless PV inverter. The AC three-level waveform and CTHD of the loads are measured using PM 300 analyzer. A simulation of CTHD on three-level transformerless PV inverter is done for the same loads using PSpice software. CTHD measurement and simulation validation are tested using statistical analysis. The simulation result shows that the value of CRM is closer to zero which indicates that the simulation is perfectly simulated, the values of RMSE are low value, this indicates that the simulation performs well, the value of NSE is closer to 1 which indicates that the simulation match perfectly with the measured CTHD. The lowest CTHD of 15.448% and 11.75% are obtained when the maximum voltage angle are 1340 and 1250 for measurement and simulation, respectively.
    URI
    http://dspace.unimap.edu.my/123456789/30637
    Collections
    • Mohd Irwan Yusoff, Dr. [19]
    • Conference Papers [2599]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback