dc.contributor.author | Ismail, Daut, Prof. Dr. | |
dc.contributor.author | Surya Hardi, Amrin | |
dc.contributor.author | Tunku Muhammad Nizar, Tunku Mansur | |
dc.contributor.author | Syafruddin, Hasan | |
dc.contributor.author | Indra, Nisja | |
dc.contributor.author | Mohd Hafizi, Idris | |
dc.date.accessioned | 2013-11-15T04:13:51Z | |
dc.date.available | 2013-11-15T04:13:51Z | |
dc.date.issued | 2012-06-18 | |
dc.identifier.citation | p. 257 - 266 | en_US |
dc.identifier.isbn | 978-967-5760-11-2 | |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/29839 | |
dc.description | The 2nd
International Malaysia-Ireland Joint
Symposium on Engineering, Science and Business 2012 (IMiEJS2012) jointly organized by Universiti Malaysia Perlis and Athlone Institute of Technology in collaboration with The Ministry of Higher Education (MOHE) Malaysia, Education Malaysia and Malaysia Postgraduates Student Association Ireland (MyPSI), 18th - 19th June 2012 at Putra World Trade Center (PWTC), Kuala Lumpur, Malaysia. | en_US |
dc.description.abstract | This paper presents induction motor behavior caused by symmetrical and unsymmetrical
faults. PSCAD/EMTD power system simulation was used for a simple model and the investigation
purpose. Voltage sags are generally caused by faults on transmission and distribution systems. The
voltage produced may be either symmetrical or unsymmetrical, depend on type of the faults.
Symmetrical fault is faults due to three-phase short circuit and causes balanced sag. Unsymmetrical
fault is faults caused by single-line to ground, phase to phase and two-phase faults and result in
unbalanced sags.
When the voltage sags occur at terminal of an induction motor, the consequences are speed loss,
current and torque peaks may appear at beginning of the fault and voltage recovery instants.
Symmetrical fault result in more severe voltage sag than unsymmetrical fault. These are indicated
in the large current peak, speed sharply drop, toque drops is deeper. Generally transient current
and transient torque appear at the beginning and the end of faults instant. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universiti Malaysia Perlis (UniMAP) | en_US |
dc.relation.ispartofseries | Proceedings of the The 2nd International Malaysia-Ireland Joint Symposium on Engineering, Science and Business 2012 (IMiEJS2012); | |
dc.subject | Symmetrical fault | en_US |
dc.subject | Unsymmetrical fault | en_US |
dc.subject | Voltage sags | en_US |
dc.subject | Induction motor behavior | en_US |
dc.title | Induction motor behavior due to symmetrical and un-symmetrical faults | en_US |
dc.type | Working Paper | en_US |
dc.contributor.url | ismail.daut@unimap.edu.my | en_US |
dc.contributor.url | bsurya@unimap.edu.my | en_US |
dc.contributor.url | tunkunizar@unimap.edu.my | en_US |
dc.contributor.url | syafruddin@unimap.edu.my | en_US |
dc.contributor.url | indra@unimap.edu.my | en_US |