• Login
    View Item 
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Electrical Systems Engineering (FYP)
    • View Item
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Electrical Systems Engineering (FYP)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Implementation of passive and active filter for harmonic mitigation

    Thumbnail
    View/Open
    Abstract, Acknowledgement.pdf (612.1Kb)
    Introduction.pdf (187.9Kb)
    Literature review.pdf (931.4Kb)
    Methodology.pdf (470.8Kb)
    Results and discussion.pdf (652.3Kb)
    Conclusion.pdf (180.4Kb)
    Reference and appendix.pdf (1.467Mb)
    Date
    2011-05
    Author
    Mohd Arif, Mat Omar
    Metadata
    Show full item record
    Abstract
    The utilization of non-linear loads has become a major concern especially in the industrial power system. The operation of the loads could draw harmonic currents and voltages which appear at the utility-consumer point of common coupling (PCC). In addition, if the harmonic occurs at the same frequency when the power system is at resonance, it could result in amplification of the harmonic distortion, or known as harmonic resonance. Three-phase Adjustable Speed Drives (ASDs) are a common source of harmonics. The variation of modulation index of a specific phase-width modulation (PWM) controller thus distributes harmonic frequencies within the main power lines. The overall harmonic components are further aggravated by the inclusion of DC link components for rectification process. The introduction of passive and active power filters (PPFs and APFs) thus reduces the overall harmonic current distortion occurring within the main power lines. Single-tuned passive filters provide fair harmonic isolation relative to its tuning frequency for harmonic resonance, although they introduce limitations on reactive power compensation. Shunt active filters cover greater range over harmonic compensation at wide harmonic frequencies. Shunt active filters provide greater performance in terms of power factor improvement compared to single-tuned passive filters.
    URI
    http://dspace.unimap.edu.my:80/dspace/handle/123456789/31441
    Collections
    • School of Electrical Systems Engineering (FYP) [218]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback