• Login
    View Item 
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Electrical Systems Engineering (FYP)
    • View Item
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Electrical Systems Engineering (FYP)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Lightning performance improvement of 132 kV transmission line by using line surge arresters

    Thumbnail
    View/Open
    Abstract, Acknowledgement.pdf (135.5Kb)
    Introduction.pdf (53.42Kb)
    Literature review.pdf (422.5Kb)
    Methodology.pdf (451.3Kb)
    Results and discussion.pdf (411.5Kb)
    Conclusion.pdf (46.81Kb)
    Reference and appendix.pdf (424.8Kb)
    Date
    2011-05
    Author
    Mohd Ammar Hakimee, Ismail
    Metadata
    Show full item record
    Abstract
    Lightning is a natural phenomenon and this condition of lightning surge may cause the travelling waves and cause the temporary increase in voltage in the transmission line system. The line voltage increase is harmful because it can destroy the equipment in transmission line system. One of the methods to improve the lightning performance of transmission lines in services is by applying the transmission line arresters. Therefore, it is necessary to analyze such as the increase voltage in order to design surge arrester that suitable for investment and select the best configuration to ensure the good performance for lightning performance improvement in transmission line system. One of the applications of ATP/EMTP simulation software are design, analyze and study the lightning activities and performance in 132 kV transmission line circuit. J.Marti model is one of the overhead lines model while Heidler model is used for simulation for fast front lightning surge. Tower model for this study is referred to model proposed by Masaru Ishii. Therefore, it is important to analyze the surge arrester configuration for the good performance of the transmission line system. The best lightning performance is configuration produced zero backflashover voltage and used less transmission line arrester.
    URI
    http://dspace.unimap.edu.my:80/dspace/handle/123456789/31442
    Collections
    • School of Electrical Systems Engineering (FYP) [218]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback