    Abstract
    In this thesis, PFC FFA5501 is introducing to reduce the harmonic and increase the power system of the system. By designing the necessary technique and methodology, the overall Power Factor (PF) and the Total Harmonic Distortion (THD) can be improved to the expectation. The thesis describes the applications of power factor correction for loads on AC motor. This thesis also presented the related techniques of FA5501 power factor correction circuit. All the data of the experiment will be measure and analyzing to find out the characteristic of the AC motor performance. By using the PFC FA5501x, the power factor was improving 0.44 and the total harmonic distortion is decreasing 9%-12%. From the result obtained from the experiment, the data can be use to calculated the economic expectation.
    URI
    http://dspace.unimap.edu.my/123456789/4621
    Collections
    • School of Electrical Systems Engineering (FYP) [218]
    • Ismail Daut, Prof. Dr. [150]

    Related items

    Showing items related by title, author, creator and subject.

    • Contactors and relays susceptibility to voltage sags 

      Mohd Yazid Zaimuri (Universiti Malaysia PerlisSchool of Electrical Systems Engineering, 2008-03)
      A contactor is electrically controlled switch used for switching a power circuit and activated by a control input which is a lower voltage or current than that which the contactor is switching. While a relay is an ...
    • Uninterruptible power supply monitoring system with Visual Basic 

      Sohiful Anuar, Zainol Murad; Mohd Nazrin, Md Isa; Norazeani, Abdul Rahman (Universiti Malaysia PerlisSchool of Microelectronic Engineering, 2006-12-29)
      In industrial process today, reliability of equipment is very important. Power supply must be able to cater the need of industrial process. In case of power failure, backup power supply system must be able to support the ...
    • Voltage sags and interruptions in a distribution system 

      Nur Zahirah Mohd Ali (Universiti Malaysia PerlisSchool of Electrical Systems Engineering, 2008-05)
      Voltage sag is the important factor in power quality problem faced by many industrial customers. The most frequently reported among various types of power quality disturbance are voltage sags. The disturbance will cause ...

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback