Show simple item record

dc.contributor.authorMd Tasyrif, Abdul Rahman
dc.contributor.authorAhmad Faizal
dc.contributor.authorA.S., Fathinul-Syahir
dc.contributor.authorSazali, Yaacob
dc.contributor.authorHazlinda, Razali
dc.contributor.authorFauziah, Mat
dc.contributor.authorNur Saifullah
dc.contributor.authorMohd Sofian
dc.date.accessioned2009-11-04T07:29:11Z
dc.date.available2009-11-04T07:29:11Z
dc.date.issued2009-10-11
dc.identifier.citationp. 1D 1 - 1D 7en_US
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/7168
dc.descriptionOrganized by School of Mechatronic Engineering (UniMAP) & co-organized by The Institution of Engineering Malaysia (IEM), 11th - 13th October 2009 at Batu Feringhi, Penang Malaysia.en_US
dc.description.abstractMetered Dose Inhalers (MDI) is used to prevent and relieve the symptoms and progression of certain diseases (asthma, chronic obstructive pulmonary disease, cystic fibrosis and bronchiectasis) by delivering the inhaled pharmaceutical aerosols (IPA) to the desired area. The MDI is easily can be placed in a pocket or purse and ready to be used instantly and these are the reasons why it is used widely. The spacer is used to avoid deposition of most IPA on the mouth throat area whereby it promotes the expansion and mixing of the IPA before it is inhaled. However, the IPA inhaling efficiency using MDI is relatively low compared to other methods. A study on the effect of various types of fan design will carry out to understand their effects on the IPA fluid dynamics characteristics. The Computational Fluid Dynamics (CFD) software was used to analyze the IPA flow pattern inside the spacer. The expected results should show that the effective fan design will generate expected characteristics of air flow inside the spacer and will give a better delivery of the IPA through MDI spacer.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlisen_US
dc.relation.ispartofseriesProceeding of International Conference on Applications and Design in Mechanical Engineering 2009 (iCADME 2009)en_US
dc.subjectMetered Dose Inhaler (MDI)en_US
dc.subjectInhaled Pharmaceuticalen_US
dc.subjectComputational Fluid Dynamic (CFD)en_US
dc.subjectEngineering fluid dynamics (EFD)en_US
dc.subjectHub tip ratioen_US
dc.subjectAxial flow fanen_US
dc.subjectAerosolsen_US
dc.subjectAerosol therapyen_US
dc.titleA study of Inhaled Pharmaceutical Aerosol (IPA) flow characteristic with various types of fan design in metered dose inhaleren_US
dc.typeWorking Paperen_US