Transient thermal analysis on convection process of circular plate used in hot surface deposition test rig
View/ Open
Date
2022-03Author
F., Jikol
M. Z., Akop
Y. M., Arifin
M. A., Salim
S. G., Herawan
Metadata
Show full item recordAbstract
The purpose of this study is to investigate the transient thermal behavior of the convection
process of a circular-shaped aluminum alloy plate used in the Hot Surface Deposition Test
(HSDT) rig. The temperature distribution and its characteristics over time are investigated
by applying certain thermal load and time dependence. As the real deposition test using
HSDT involves a process of detaching the aluminum alloy circular plate from the heater
block, the transient thermal analysis will provide a base for estimating the time required for
the hot plate to cool down to room temperature (25°C-27°C) and safe to be handled. The
process of modeling the geometry, meshing, applying the boundary conditions, and
evaluating results are conducted experimentally using ANSYS Release 16.2 software. It is
indicated in the analysis results that the aluminum alloy circular plate with higher internal
temperature undergoes a longer convection process to cool down to room temperature.
These results are used to estimate the cooling down time of the hot plate in the real
deposition test.