Charge measurement system
Abstract
This project discusses the design of charge measurement meter. This
instrument was used to measure the rate of charges for different surroundings.
Construct a capacitor plate to capture the charge, connect the capacitor plate to
capacitor, then connected it to amplifier to enlarge the DC voltage signal. Before that,
the amplification of the operational amplifier was tested. The enlarged voltages
obtained are then converted back to the original voltage value produced. Finally, the
rate of charge was calculated by using the formula. The results obtained shows that
the rate of charge at indoor surrounding is higher than outdoor.