• Login
    View Item 
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Environmental Engineering (FYP)
    • View Item
    •   DSpace Home
    • Final Year Project Papers & Reports
    • School of Environmental Engineering (FYP)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The assessment of chemical compounds in indoor air of student hostels in UniMAP

    Thumbnail
    View/Open
    Abstract,acknowledgement.pdf (689.8Kb)
    Introduction.pdf (611.1Kb)
    Literature Review.pdf (618.0Kb)
    Methodology.pdf (759.0Kb)
    Result and Discussion.pdf (692.0Kb)
    Conclusion and Recommendation.pdf (596.9Kb)
    Reference and Appendics.pdf (619.8Kb)
    Date
    2016-06
    Author
    Nursyuhada, Abd Lah
    Metadata
    Show full item record
    Abstract
    Indoor Air Quality (IAQ) consists of several components such as type and concentration of pollutant that emitted in air environment, thermal comfort of occupant and adverse effect to human towards the inhalation of pollutants. This study aim to investigate IAQ at Pauh Putra and Tan Sri Aishah Ghani hostel in Universiti Malaysia Perlis (UniMAP). The selected chemical compounds in this study are total volatile organic compound (TVOC), carbon dioxide (CO₂), carbon monoxide (CO) and ozone (O₃). Thermal comfort assessment such as temperature and relative humidity (RH) were evaluated as well in these building. The TVOC, CO₂, CO and O₃ data at Pauh Putra hostel ranged between not detected to 0.17 ppm, 420 ppm to 567 ppm, not detected to 2.20 ppm and not detected to 0.028 ppm respectively. While TVOC, CO₂, CO and O₃ at Tan Sri Aishah Ghani hostel ranged between not detected to 0.13 ppm, 425 ppm to 697 ppm, not detected to 1.40 ppm and not detected to 0.020 ppm respectively. The outdoor TVOC, CO₂, CO and O₃ at Pauh Putra hostel ranged between not detected to 0.05 ppm, 437 ppm to 807 ppm, not detected to 0.10 ppm and not detected to 0.010 ppm respectively. For outdoor TVOC, CO₂, CO and O₃ at Tan Sri Aishah Ghani hostel ranged between not detected to 0.06 ppm, 447 ppm to 472 ppm, not detected to 1.80 ppm and not detected to 0.040 ppm respectively. The mean Indoor Outdoor Ratio (IOR) values for TVOC, CO₂, CO and O₃ was 0.84, 1.12, 15.53, and 0.62 respectively. This value suggesting that the source of chemical pollutants comes from indoor building. The temperature recorded at Pauh Putra hostel ranged between 30.4⁰C-35.1⁰C and 30.8⁰C-34.2⁰C recorded in Tan Sri Aishah Ghani hostel. RH value recorded ranged between 39%-61% at Tan Sri Aishah Ghani and 40%- 57% at Pauh Putra hostel. The observations of IAQ were below the Malaysia guideline (Code of Practice, 2010) which indicates that the risk of adverse health effects to human is low. Nevertheless, these pollutants require continuous observation as they have intensive properly to humans and able to resulted to Sick Building Syndrome (SBS).
    URI
    http://dspace.unimap.edu.my:80/xmlui/handle/123456789/83549
    Collections
    • School of Environmental Engineering (FYP) [638]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback