WSS investigation in microfluidic FFS channel at Re 500
Date
2014-01Author
Zaliman, Sauli, Dr.
Retnasamy, Vithyacharan
Taniselass, Steven
Nor Shakirina, Nadzri
Hsio Mei, Tan
Khairul Anwar, Mohamad Khazali
Nooraihan, Abdullah
Metadata
Show full item recordAbstract
Wall shear stress (WSS) is one of the important variables in microfluidic devices. In this paper WSS distribution for a microfluidic device in Forward Facing Step (FFS) configuration has been investigated using Reynolds number 500 and step height 1μm. Numerical simulation was performed usingAnsys-CFX software with the assumption of Newtonian fluid and laminar condition. The simulation result showed that wall shear stress distribution increased after the fluid passing through the step.