Show simple item record

dc.contributor.authorMuhammad Ammar, Mat Deri
dc.contributorSchool of Environmental Engineeringen_US
dc.date.accessioned2022-01-17T03:59:20Z
dc.date.available2022-01-17T03:59:20Z
dc.date.issued2014-06
dc.identifier.urihttp://dspace.unimap.edu.my:80/xmlui/handle/123456789/73434
dc.descriptionAccess is limited to UniMAP community.en_US
dc.description.abstractWater should be purified for a better life style. In this report, this study conducted to investigate physicochemical of river water in Perlis, based on the classification of National Water Quality Standards for Malaysia (INWQS) and a statistical regression analysis method for the nine type parameters. This technique was based study and calculate the correlation coefficients between various physicochemical parameters of river water. Nine types of physicochemical parameters studied were BOD, COD, DO, TSS, turbidity, Phosphate, Ammonical Nitrogen, pH and temperature. Samples were collected during November 2013 to January 2014 at the four different points which Kangar Wet Market (station 1), Pengkalan Asam (station 2), Tebing Tinggi (station 3) and Kuala Perlis (station 4). The finding from the study shows, Perlis water quality is classified as slightly polluted because all types of parameters are tested showed in class IIb and III (INWQS). The results revealed that the systematic calculations of correlation coefficients between water parameters and regression analysis provide useful means for rapid monitoring of water quality. There are four highest reading recorded at each sampling station such as station 1 with pair COD and turbidity (R=0.843), station 2 is turbidity and TSS (R=0.777), station 3 is BOD and TSS (R=0.936) and station 4 is BOD and turbidity (R=0.901). The R value must be (R>0.5) to produce the strong relationship correlation. The overall result shows, parameters turbidity with TSS also produces a high data range when paired with other parameters and that is showing all the parameters in Perlis river water was manipulated by turbidity and TSS. Recommendations can be given that, river water quality can be checked effectively by controlling the conductivity of water.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.subject.otherInvestigateen_US
dc.subject.otherPhysicochemicalen_US
dc.subject.otherRiver Wateren_US
dc.subject.otherWater qualityen_US
dc.titleInvestigate physicochemical of river water in Perlisen_US
dc.typeOtheren_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record